Zoll r series defibrillator manual. ZOLL R Series Monitor Defibrillator Rev J : User guide 2019-02-17

Zoll r series defibrillator manual Rating: 8,8/10 632 reviews

Zoll R Series Defibrillator and Monitor Featuring See

zoll r series defibrillator manual

If your unit supports Remote Sync, you must also press the Sync softkey. The charge ready tone then stops and the defibrillator remains in Remote Sync mode. Two voice prompts are available for. For use with adult, pediatric, and neonatal patients. Maintenance Frequency Visual Inspection Once per day, inspect Code Readiness indicator. A-2 Delivered Energy at Every Defibrillator Setting into a Range of Loads.

Next

Zoll R Series BLS Defibrillator

zoll r series defibrillator manual

Before replacing the Adult plate, be sure to clean the pediatric plate and surrounding area thoroughly. Defibrillator Dashboard optimizes defibrillator readiness and increases efficiency for the biomedical engineering team. Does the unit show signs of excessive wear? Do not permit gel to accumulate between the paddle electrodes on the chest wall gel bridge. If using defibrillator gel pads, make sure that the size of the pad is large enough to cover the entire paddle electrode area. Survival depends on compressions that are fast—but not too fast—and deep—but not too deep—with full release, minimal interruptions, and appropriate ventilation.

Next

Zoll

zoll r series defibrillator manual

Defibrillation Event Format Pre-Shock Figure 11-3. To print a specific test, use the Prev Test and Next Test softkeys to select the test, then press Print Test, or press Print Test Log to print the log of all of the tests. If it is necessary to pace for more than 30 minutes, periodic inspection of the underlying skin is strongly advised. Full disclosure recordings are erased at the same times as Summary Reports. If no intrinsic rate exists, use 100 ppm.

Next

Zoll R Series Defibrillator and Monitor Featuring See

zoll r series defibrillator manual

If you're facing a time constraint, please select an expedited shipping option during checkout. Transferring Device Check and Activity Log Files to a Compact Flash Card Make sure that a compact flash card is installed in the slot on the left side of the device. If the Confirm softkey is not pressed within 10 seconds, the unit will revert back to semiautomatic operation. Verify that Sync markers appear with each R-wave. It is displayed in the lower left corner.

Next

Zoll

zoll r series defibrillator manual

Patient Impedance 15 - 300 ohms Range Energy display Screen shows selected and delivered energy. No need to do a 30 J manual test; simply verify the green check mark is visible during your shift check. The month field will be highlighted. Ready as the R Series conducts an automated self-test once a day. No need to do a 30 J manual test; simply verify the green check mark is present during your shift check.

Next

ZOLL R SERIES SERVICE MANUAL Pdf Download.

zoll r series defibrillator manual

A total of 1000 Code Readiness test records can be stored in internal memory. The external printer parts should be cleaned with a damp, soft cloth only. The code markers are removed from the display after 10 seconds. Action: Contact the Network Administrator for assistance. Strip chart paper flows out of printer compartment.

Next

Zoll R Series Defibrillator and Monitor Featuring See

zoll r series defibrillator manual

Condition Remarks Unit clean, no spills, clear of objects on top, case intact 2. The rate is updated every beat. Rectilinear Biphasic Waveform at 50 Joules 25 Ohm 50 Ohm 75 Ohm 100 Ohm 125 Ohm 150 Ohm 175 Ohm 200 Ohm Figure A-9. Allows defib self-test when paddles are stowed in their respective wells. Press the Manual Mode softkey. Defibrillation Event Format Post Shock 9650-0904-01 Rev.

Next

Zoll R Series Defibrillator and Monitor Featuring See

zoll r series defibrillator manual

Two voice prompts are available for. Continue Patient Care Continue patient care according to medical protocols. Pacer Mode Selected Format Asynchronous Pacing 10—4 www. We select the best carrier depending on the specific product. Corruption may result on the data card. If the patient is in ventricular fibrillation and defibrillation is successful but cardiac standstill asystole ensues, you should use the pacemaker. Note: When the event summary memory and full disclosure memory are filled, data recording stops.

Next

Zoll R Series Defibrillator (Recertified)

zoll r series defibrillator manual

The unit should not turn on. Use appropriate precautions when disposing of contaminated electrodes. To access Defib Mentor mode: 1. If the unit is on for over 100 minutes, the elapsed time will roll over to 0. Connect the lead wires appropriate to each test to the Fluke Biomedical 4000 or equivalent. To avoid risk of electrical shock, do not touch the gelled area of the hands-free therapy electrodes while pacing. Note: When using appropriate pediatric resuscitation electrodes, the 75-joule setting is replaced by 70- and 85-joule settings.